Short answer: a three-phase air conditioner runs on three phases at 400 V instead of one phase at 230 V. You find it among professional units from 36,000 BTU up: floor-standing, cassette, ducted and floor-ceiling models. You need one when the site has a three-phase supply and you want more than 48,000 BTU or do not want the whole load on a single phase. Up to 48,000 BTU there are single-phase models in stock too. We connect the unit to the three-phase supply, and the site survey is free in Varna and up to 200 km from it.
The question usually comes up when choosing a floor-standing or cassette unit for a shop, restaurant or office. The product card says „3~ / 380 – 415 V“ and the buyer does not know whether it suits the site. Below is what this means, from what capacity it appears and what the electrical board needs.
What a three-phase air conditioner is
Most homes in Bulgaria have a single-phase supply: phase and neutral, 230 V. Commercial and industrial premises, and some houses, usually have a three-phase supply: three phases and neutral. The voltage between two phases is 400 V.
A three-phase air conditioner is one whose outdoor unit runs on three phases. The indoor unit is the same as in the single-phase model. The difference is in the compressor and the electronics of the outdoor unit. On the product card you see it in the „Power supply“ field:
- 1~ / 220 – 240 V means a single-phase model;
- 3~ / 380 – 415 V means a three-phase model.
Many manufacturers make the same outdoor unit in both versions. In the Daikin Sky Air Advance series (RZASG) there are single-phase models marked MV and three-phase models marked MY. Some brands put „TRI“ or „three-phase“ in the name.
From what capacity air conditioners become three-phase
The wall-mounted units in stock are single-phase. The three-phase models in stock are professional systems from 36,000 BTU up. Between 36,000 and 48,000 BTU both versions exist. Above 48,000 BTU the models in stock are three-phase, and single-phase LG cassette, ducted and floor-ceiling models with 60,000 BTU are available on request. The data come from the „Power supply“ field of the product cards of models in stock as of 30.10.2026:
| Type | Three-phase models | Single-phase models from 34,000 BTU |
|---|---|---|
| Floor-standing | 48,000 – 55,000 BTU | 45,000 BTU |
| Cassette | 36,000 – 60,000 BTU | 34,000 – 48,000 BTU |
| Ducted | 36,000 – 60,000 BTU | 34,000 – 48,000 BTU |
| Floor-ceiling | 36,000 – 55,000 BTU | 36,000 BTU |
Capacity is chosen by floor area and by the load in the room. As a guide: 24,000 BTU for 50 – 70 m² and 36,000 BTU for 70 – 100 m². The full table is in the article how many BTU do I need.
Why powerful models switch to three phases
At the same power, a three-phase unit spreads the current over three conductors. That is why the current in each phase is about three times lower than in a single-phase unit that draws everything from one phase. Lower current means a smaller fuse and a more even load on the board.
An example from Daikin data for the Sky Air Advance series (RZASG):
- the single-phase outdoor units 100, 125 and 140 need a fuse of up to 25 A or up to 32 A depending on the model;
- the three-phase outdoor units with the same numbers need a fuse of up to 16 A per phase.
If the site has a single-phase supply, a large single-phase unit may require a higher contracted power from the distribution company. If the site is three-phase, a three-phase model usually fits into the board more easily.
When you need a three-phase unit and when single-phase is enough
A three-phase model makes sense when:
- the site already has a three-phase supply, as most shops, restaurants, warehouses and workshops do;
- you need more than 48,000 BTU: in stock these models are three-phase, and single-phase ones are available on request;
- several powerful units will run on site and the load has to be spread across the phases;
- one of the phases already carries a large load: an oven, refrigerated displays, a water heater.
A single-phase model is the better fit when:
- the site has a single-phase supply only, for example a flat or a small office in a residential building;
- up to 48,000 BTU is enough, because single-phase models exist up to that capacity;
- changing the supply would take more time or money than the difference between the models.
A three-phase supply on site does not oblige you to buy a three-phase unit. A single-phase unit is connected to one of the phases of the three-phase board. With several single-phase units it is better to spread them across different phases.
What the site needs: board and supply
Before choosing a three-phase model, check four things:
- Three-phase supply. The board has three phases and a three-phase meter. If you are not sure, this is checked during the survey.
- Spare contracted power. The new air conditioner adds to the load the site already has.
- A dedicated line for the air conditioner. Manufacturers require its own circuit breaker and residual current protection. The cable cross-section and the breaker rating are in the installation manual of the specific model.
- A cable route to the outdoor unit. The three-phase cable runs along the piping route or separately to the outdoor unit location.
If the site has no three-phase supply or the power is not enough, the account holder applies for the change to the distribution company. For Varna, Dobrich and Shumen this is Elektrorazpredelenie Sever, for Burgas it is Elektrorazpredelenie Yug. Documents and deadlines are on the website of the respective company. This is a procedure separate from buying and installing the air conditioner, so start it in good time.
Installation and price of a three-phase air conditioner
A three-phase air conditioner is installed like the single-phase model of the same type. Only the electrical connection of the outdoor unit differs. We connect the unit to the three-phase supply of the site. If a new line from the board is needed, it is assessed during the survey and listed separately in the quote.
Prices for standard installation of floor-standing, ducted and cassette units bought from Svit Komfortu, excluding the piping route:
| Capacity | Standard installation |
|---|---|
| up to 30,000 BTU | 220 € |
| 36,000 – 48,000 BTU | 245 € |
| 50,000 – 90,000 BTU | 270 € |
The three-phase models in stock start at 36,000 BTU, so they fall into the second or third row. The price for floor-ceiling units is given after the survey. What is specific to a cassette (ceiling, condensate, piping) is described in the article cassette air conditioner installation, and all prices and the request form are on the page air conditioner installation.
The process is the same for every site: a free survey, a written quote within 24 hours, installation by certified technicians and a 1-year warranty on the installation. We also work at weekends. We do not prepare HVAC designs, but we supply and install according to your design if you have one.
Three-phase models in the catalogue
Three-phase models are in the professional systems categories. The prices below cover all models in the category, single-phase ones included:
- floor-standing air conditioners, from 1 330 €;
- cassette air conditioners, from 940 €;
- ducted air conditioners, from 850 €;
- floor-ceiling air conditioners, from 1 303 €.
For example, the three-phase Kaisai cassette models marked TRI (36,000 – 55,000 BTU) are from 2 403 €. All types and a comparison between them are in the category professional air conditioners. We carry out surveys in Varna and up to 200 km from it: Dobrich, Shumen, Burgas, Silistra, Razgrad, Targovishte and the coastal resorts.
Frequently asked questions
What does a three-phase air conditioner mean?
It is an air conditioner whose outdoor unit is powered by three phases at 400 V. The product card says „3~ / 380 – 415 V“. A single-phase model says „1~ / 220 – 240 V“.
From how many BTU is an air conditioner three-phase?
In stock, three-phase models start at 36,000 BTU. Up to 48,000 BTU there are single-phase models in stock too. Above 48,000 BTU the models in stock are three-phase, and single-phase models with 60,000 BTU are available on request.
Can a three-phase air conditioner run on a single-phase supply?
No. A three-phase outdoor unit needs three phases. If the site has one phase only, choose a single-phase model: up to 48,000 BTU in stock or with 60,000 BTU on request. The other option is to apply for a three-phase supply to the distribution company.
Can a single-phase air conditioner be used on a site with a three-phase supply?
Yes. The single-phase unit is connected to one of the phases of the board. With several units it is better to spread them across different phases.
Do you connect the three-phase supply during installation?
Yes, we connect the air conditioner to the three-phase supply of the site. A new line from the board, if needed, is assessed during the free survey and listed in the quote.
How much does installing a three-phase air conditioner cost?
For floor-standing, ducted and cassette units bought from us, standard installation is 245 € for 36,000 – 48,000 BTU and 270 € for 50,000 – 90,000 BTU, excluding the piping route. For floor-ceiling units the price is given after the survey.