Short answer: a fan coil unit (fan convector) is a water-fed heat emitter with a fan. It gives full output at water of about 45 °C, so the heat pump runs more efficiently than with radiators, and in summer the same unit cools. In our calculation for a 100 m² house that is 326 € of electricity per season against 413 € with radiators. We price the units and the installation after a free site visit.
The question „convectors for a heat pump“ comes from people who already know that an air-to-water heat pump wants low-temperature emitters. A new house has underfloor heating, while an old one usually has radiators. Fan coil units are the third way, and in Bulgaria it is underrated. We described it briefly in the article heating with a heat pump and radiators. Here is the full choice: types, output, the bill and when it is not worth it.
What a fan coil unit is
Inside there is a water coil and a fan. Hot water from the heat pump passes through the coil, and the fan blows air across it. Forced airflow is the reason the unit keeps its output with cooler water. An ordinary radiator relies on natural convection and radiation, so at 45 °C it gives much less.
Do not confuse it with the electric convector you plug in. This one is connected to the water system and has no heating element. The comparison with electric convectors is in the article cheap electric heating.
Convector, radiator or underfloor: the seasonal bill
We take an insulated house and the same basis as in the heat pump or air conditioners for a house calculation: 8,250 kWh of heat per season at 100 m² and 12,400 kWh at 150 m², electricity at 0.15 €/kWh. SCOP is an assumed guide: 4.0 for underfloor, 3.8 for fan coil units at 45 °C water and 3.0 for radiators. The exact value depends on the heat pump model and the unit.
| Emitters in the house | House 100 m² | House 150 m² |
|---|---|---|
| Underfloor, SCOP 4.0 | 2,063 kWh – 309 € | 3,100 kWh – 465 € |
| Fan coil units, SCOP 3.8 | 2,171 kWh – 326 € | 3,263 kWh – 489 € |
| Radiators, SCOP 3.0 | 2,750 kWh – 413 € | 4,133 kWh – 620 € |

Fan coil units come out about 20% below radiators and slightly above underfloor. The gap to underfloor is 17–24 € per season. So a fan coil unit makes sense where underfloor is not an option: in an old house or in a room where you do not want to break up the flooring.
Types of fan coil units and where they go
- Wall-mounted. Sits high on the wall like an air conditioner. Suits a room where you also want cooling, without work on the floor.
- Floor-standing (cabinet). Goes on the floor under the window in place of an old radiator. The easiest to connect to the existing pipes.
- Built into the floor or the wall. Invisible, but needs building work. Considered during a renovation.
- Ceiling or cassette. Suits a large living room, but needs space in the ceiling and a condensate drain.
- Ducted. Hidden behind a suspended ceiling, the air leaves through grilles. For a new house with a design project.
To replace a radiator in an old house, a floor-standing or wall-mounted unit is usually chosen. Which one fits exactly, we find out at the site visit.
Output: how many units and which
The output of a unit is calculated from the heat loss of the room at 45 °C water, not from floor area. A 1 kW radiator at 75 °C gives noticeably less at 45 °C, so it is replaced with a larger one or with a fan coil unit. At the visit we measure the losses room by room and tell you how many units you need. The total output of the machine is calculated separately, from the losses of the whole house. How many BTU a room needs is in how many BTU you need, and heat pump for a house – price has a guide by floor area.
Cooling in summer
The same heat pump runs in reverse and chills the water. The units then blow cool air, like an air conditioner. There are two conditions. First, the unit must have a condensate tray with a drain to a sewer, otherwise it drips. Second, a two-pipe system switches between heating and cooling for the whole season: you cannot heat one room and cool another. Radiators and underfloor do not cool as easily.
Noise, condensate and the buffer tank
A fan means sound. In a bedroom a model with a quiet mode is chosen and placed away from the head of the bed. Condensate appears only in cooling and is drained to a sewer or a condensate pump. If the water circuit holds a small volume, for example only a few units in a small house, a buffer tank is needed too, otherwise the machine cycles on and off. We determine its size after the visit, and the price is „after a site visit“.
When a fan coil unit is not the right choice
- The house is new and can get underfloor: it is slightly more economical and silent.
- The radiators are large and sufficient at 50–55 °C: then you do not pay for new units.
- You do not want sound in the bedroom and do not need cooling: a wall-mounted or floor-standing unit brings no benefit there.
The sensible layout in an insulated house is mixed: fan coil units in the living room and bedrooms, radiators in the hallway and utility rooms. This saves money and gives cooling where it is wanted.
Free site visit in Varna and the region
We supply and install fan coil units and buffer tanks together with a heat pump installation. At the visit we look at what emitters there are, what the water volume is, where the outdoor unit goes and where the condensate goes. After that you get a price for the whole system. The heat pump models are in the section air-to-water heat pumps, and what the work includes is described on the page heat pump installation in Varna. If you are choosing between an all-in-one machine and one with an indoor module, see monobloc or split heat pump.
Frequently asked questions
What is a fenkoyl?
It is another name for the fan convector: a water-fed unit with a fan that works with water from the heat pump or boiler.
Does a heat pump work with fan convectors?
Yes. The units give full output at water of about 45 °C, so they suit an air-to-water heat pump better than radiators.
Can I replace radiators with fan convectors without renovation?
Often yes. A floor-standing or wall-mounted unit connects to the existing pipes, but whether the pipes and the water volume are enough, we check at the visit.
Do fan convectors cool in summer?
Yes, if the system is two-pipe, the units have a condensate tray and the heat pump has a reverse mode. Then the whole circuit switches at once.
How much do convectors for a heat pump cost?
The price depends on the type, output and number of units, so we give it after a free site visit, together with the installation and the buffer tank if needed.