Air conditioner noise: which sounds are normal and when to stop the unit

Updated 5 min read Air conditioners – useful tips

Air conditioner outdoor unit on a balcony

Short answer: gurgling, a soft hiss, cracking and clicking are normal sounds of a working air conditioner. Daikin explains them by the movement of the refrigerant, the valves and the casing expanding as the temperature changes. Loud rattling, grinding or an unfamiliar noise during operation is not normal: stop the unit, switch off the power at the breaker and call a technician.

An air conditioner has two units. The indoor unit holds the fan, the airflow flap and the condensate tray. The outdoor unit holds the compressor, the fan and the valve that reverses the refrigerant flow. Each of these parts makes its own sound, so first find out where the noise comes from.

What the sound is and whether it is normal

Sound Where it comes from Is it normal
Gurgling, like running water refrigerant flowing in the pipes, or condensate draining in cooling mode yes
Blowing or hissing when the mode changes the refrigerant changes direction, for example from cooling to heating yes
Whistling in winter refrigerant flowing during defrost yes
Cracking or ticking the casing slightly expands and contracts as the temperature changes yes
Clicking during operation or at rest the refrigerant valves or electrical parts switching yes
Bubbling from the indoor unit outside air entering through the drain hose open a window, check the hose
Loud rattling, grinding, unfamiliar noise a fault or a loose part no, stop the unit and call a technician

The normal sounds in the table follow the Daikin user reference guide for wall-mounted air conditioners and the Daikin troubleshooting page.

The indoor unit is noisy

Gurgling from the indoor unit is usually the refrigerant or the condensate water. Daikin states that clicking comes from the valves and electrical parts, and that at start and stop you hear the flap moving into position. These sounds are short and do not grow louder over time.

If you hear bubbling from the unit, Daikin links it to the drain hose: in a tightly closed room with an extractor running, or in strong wind, outside air enters through the hose. Open a window or switch off the extractor. Turning the end of the hose in a different direction also helps, and the installer can fit a check valve on the hose. If the unit is also dripping water, see air conditioner dripping water.

If the airflow itself bothers you, for example at night, lower the fan speed. Daikin describes a quiet mode for the indoor unit that reduces the noise. How to choose a quiet unit for the bedroom is covered in air conditioner for the bedroom.

The outdoor unit is noisy

In winter the outdoor unit defrosts from time to time. Heating stops, you hear running water or whistling, and steam may come out of the unit. Daikin advises waiting about 3 to 10 minutes. We cover this mode in detail in air conditioner defrosting.

Rattling and vibration passed on to the wall or the railing can come from the installation. Daikin states that the installation site must withstand the weight and vibration of the unit, and that the outdoor unit should not be placed where its noise disturbs people. Check that the bracket is firmly fixed and that the unit does not touch the wall or the railing. For common installation mistakes, see air conditioner installation mistakes.

Clapping when the extractor is on

Daikin also describes a clapping sound. It appears when an extractor hood or fan draws air out of the room while the doors and windows are closed. Open the door or window, or switch off the device that draws the air.

When to stop the air conditioner

For an unusual noise during operation, Daikin advises stopping the unit, switching off the power at the plug or the breaker and contacting the dealer. The same applies if the noise comes with a burning smell. What the different smells mean is described in air conditioner smells. Do not switch the unit back on before it has been checked. This needs an air conditioner repair.

What to check yourself

  • Where the sound comes from: the indoor or the outdoor unit.
  • When you hear it: at start, when the mode changes, in winter during defrost, or all the time.
  • Whether an extractor is running with the windows closed.
  • Whether water drains from the hose outside without bubbling in the room.
  • Whether the outdoor unit touches the wall, the railing or objects on the balcony.

Write down when and how the noise appears. Daikin advises stating the symptoms, the full model name and the installation date when you call.

Maintenance, repair or a new air conditioner

If the unit has not had air conditioner maintenance for more than a year, start with that. For a standard wall split it costs 42 €. Rattling in the compressor, a grinding fan or vibration from a loose bracket needs an on-site inspection. How to prepare the unit for the season is described in seasonal air conditioner preparation.

If the unit is old and the repair is not worth it, inverter air conditioners are in stock from 300 €. Models and prices with installation are collected in air conditioners in Varna. The site visit for a new air conditioner is free in Varna and up to 200 km from it.

Frequently asked questions

Is it normal for an air conditioner to make noise?
Yes, if the sound is quiet and short: refrigerant gurgling, valves clicking, the casing cracking as the temperature changes. Loud rattling, grinding or a new unfamiliar noise is not normal.

Why does the air conditioner crack?
Daikin explains cracking and ticking by the casing slightly expanding and contracting when the temperature changes. This is not a fault.

Why does the outdoor unit hiss in winter?
Usually the unit is defrosting. Heating stops for about 3 to 10 minutes, you hear running water or whistling, then operation continues.

Why is there bubbling from the air conditioner?
Outside air enters through the drain hose, usually with an extractor running and the windows closed, or in strong wind. Open a window. If that does not help, the hose needs to be checked.

Can I use the air conditioner if it rattles loudly?
No. Stop it, switch off the power at the breaker and call a technician.

How much does maintenance cost?
For a standard wall split, maintenance is 42 €. For cassette and multi-split systems we give a quote after a short consultation.