The air conditioner does not heat: causes and what to check yourself

Updated 5 min read Air conditioners – useful tips

Air conditioner outdoor unit with frost on a balcony in winter

Short answer: when an air conditioner does not heat, first check the HEAT mode, the set temperature, the remote control batteries, the circuit breaker and the filters. Then wait up to 10 minutes, because the unit may be warming up or defrosting. If it then blows cold air, shows an error code or there is ice on the pipes, you need a technician.

Some causes can be checked without tools. The others show in how the unit behaves and in what the thermometer outside reads.

What to check in five minutes

  1. The mode. The remote should show HEAT or the sun symbol.
  2. The temperature. The set value must be above the room temperature, otherwise the unit has no reason to heat.
  3. The remote. Replace the batteries, because a weak signal looks like a fault.
  4. The power. See whether the breaker in the panel has tripped. If it trips again, do not reset it and call a technician.
  5. The filters. A clogged filter reduces both airflow and heating. How to clean them is described in seasonal air conditioner preparation.
  6. The outdoor unit. Remove snow and leaves if you can reach them safely, and leave at least 30 cm of free space at the sides and rear.

Mode, degrees and fan are covered step by step in setting an air conditioner for heating, and the signs are explained in air conditioner remote symbols.

When it is normal for the unit not to heat straight away

What you see Cause How long to wait
It is on HEAT, but the indoor unit does not blow warm-up, so that no cold air comes out Daikin states 1 – 4 minutes, longer in cold weather; give it up to 10 minutes
You switched it off and straight back on unit protection about 3 minutes
It stops blowing and steam comes from the outdoor unit defrosting usually a few minutes, up to about 10

How the cycle works and when it signals a fault is described in air conditioner defrosting. If it stops every 10 – 15 minutes, that is no longer normal.

It is below the model’s limit outside

An air conditioner takes heat from the outdoor air, so at low outdoor temperatures the heating may not be enough. The lower limit is on the model’s product card, in the heating temperature specification.

Lower limit Models in stock Example Prices
down to −15 °C over 200 TechPoint TCP MAXCOOL from 300 €
from −20 to −23 °C over 80 TechPoint NPT X-PRO Nordic from 325 €
−25 °C over 50 Nippon KFR ION Nordic from 420 €
−30 °C and below 7 Gree S-Cool from 1 044 €

For Varna, −15 °C is usually enough. If you heat only with an air conditioner or live inland, see the ranking of heating air conditioners by SCOP.

It blows warm air, but the room stays cold

In that case compare the capacity with the floor area first. 9,000 BTU is for 15 – 25 m², 12,000 BTU for 25 – 35 m², 18,000 BTU for 35 – 50 m² and 24,000 BTU for 50 – 70 m². A detailed calculation is in how many BTU I need.

If the capacity is right, but the unit is old and has not been serviced for more than a year, the likely cause is a dirty heat exchanger or low refrigerant.

It blows cold air in heating mode

In the first few minutes this can be warm-up or defrosting. If the air is still cold after 10 minutes on HEAT, settings will no longer help. Possible causes are low refrigerant, a sensor, the valve that reverses the cycle, or the electronics. Switch the unit off and book an air conditioner repair.

One indoor unit of a multi-split does not heat

The indoor units share one outdoor unit. Daikin states that they do not run in incompatible modes, such as cooling and heating: the unit without priority goes into standby. Set all units to HEAT and try again. There is more in what a multi-split system is.

When to call a technician

  • The display shows an error code or the lamps flash in a set pattern.
  • There is ice on the pipes or on the indoor unit.
  • Ice on the outdoor unit does not melt and grows with every cycle.
  • The breaker trips again or there is a burning smell. Stop the air conditioner at once. Other smells and their causes are described in air conditioner smells.
  • After all the checks there is still no warm air.

Do not top up refrigerant yourself. A working system is sealed, so a lower level means a leak, and it is found and fixed before recharging.

Servicing, repair or a new air conditioner

If the unit runs but heats weakly, start with air conditioner servicing. For a standard wall-mounted split it costs 42 €. An error code, ice or cold air requires on-site diagnostics, and the repair price depends on the fault and the parts.

If the capacity or the model’s lower limit is not enough, the solution is a new unit. Inverter air conditioners in stock start from 300 €, and how to choose a model for winter is described in air conditioner for heating. Standard installation is 150 € up to 14,000 BTU and 180 € from 16,000 to 24,000 BTU when the unit is bought from us. The survey for a new air conditioner is free in Varna and up to 200 km from it.

Frequently asked questions

Why does the air conditioner blow cold air instead of warm?
In the first few minutes the unit is warming up or defrosting. If the air on HEAT is still cold after 10 minutes, the cause is in the unit and diagnostics are needed.

How long should I wait for the air conditioner to start heating?
Usually a few minutes. Daikin states 1 – 4 minutes of warm-up, longer in cold weather. Give the unit up to 10 minutes.

A new air conditioner does not heat. What should I do?
Check the HEAT mode and the set temperature and wait for the warm-up. If the problem remains and we installed the unit, contact us: the installation has a 1-year warranty.

Are the causes different for Daikin, Mitsubishi or Gree?
The causes are the same. The error codes and symbols differ, so look them up in the manual for your model.

Can low refrigerant stop an air conditioner from heating?
Yes. Low refrigerant weakens heating and can cause ice on the pipes. A working system does not lose refrigerant, so the leak is looked for first. What a lowered level means is covered in air conditioner refrigerant.

Down to what outdoor temperature does an air conditioner heat?
It depends on the model. For the inverter models in our catalogue the lower limit is from −10 to −35 °C and is shown on each model’s product card.